Copyright 2024 by Rex Instruments 201401004426 (1080500-W) | Thermal Imaging Camera Johor Bahru (JB), Malaysia
 
 
| Cancel
Mobile :: Products Masthead
PIE 334Plus mA Loop Diagnostic Calibrator

PIE 334Plus mA Loop Diagnostic Calibrator

Product Description

 
 
 
   
 
Find hidden loop problems – Ground Leak Detected with Loop Diagnostics
Have you ever replaced a “faulty” transmitter only to find the problem was somewhere else in the loop? And did you end up throwing the transmitter away after you fixed the other problem “just in case” the transmitter was faulty?
 
If you find a loop where the transmitter is calibrated correctly but all the readings elsewhere in the loop have a fixed offset, this is due to Zero Shift. This zero shift is typically caused by some current in the loop bypassing the transmitter. This might be caused by ground faults, moisture or corrosion.
 
If you have some loops that are erratic after it rains, there may be moisture present in a junction box where insulation has broken down. Turn on Ground Leak Detection and use the PIE 334Plus to power up the loop. Any current that isn’t controlled by the transmitter or other current control element will be indicated as leakage on the PIE 334Plus display.
 
The PIE 334Plus powers up the 2-Wire transmitter or loop and indicates the total current and the uncontrolled current. This provides information useful in troubleshooting loop errors.
  • Calibrate Milliamp Instruments
    Source 0.00 to 24.00 mA & -25.0 to 125.0% of 4-20 mA
    Read 0.00 to 52.00 mA
    Read -99.99 to 99.99 V
    Simulate 2-Wire Transmitter, Power & Read Transmitters
    Menu Selectable 250 Ohm resistor for HART compatibility
  • Calibrate with Accuracy
    Accurate to ±0.025% of Span at 4.00 & 20.00 EZ-CHECK outputs
  • Easy-to-Read Backlit Display
  • Locate Loop Current Leakages
    Automatic indication of Loop Current and Leakage Current. Measure ground current leakage from faulty wiring, flooded conduit and corrosion bridges. Leakage typically appears as a Zero Shift and helps you decide if the transmitter needs calibration or if there is a problem in the loop wiring.
  • Faster Calibrations
    Three output EZ-CHECK switch
    2 speed EZ-DIAL
    Stepping & Ramping
  • Includes Rubber Boot, Test Leads & Deluxe Hands Free Carrying Case (020-0211)
  • Optional Accessories
    AC Adaptor 120 V (020-0101); 240 V (020-0100)
    NiMh Batteries & Charger 120 VAC/12V DC (020-0103)
    Magnetic hanging strap(020-0236)
    mA Loop Diagnostic Calibrator PIE 334Plus | find hidden loop problems quantity
     

 

 
 
 
 
 
 
Copyright 2024 by Rex Instruments 201401004426 (1080500-W) | Thermal Imaging Camera Johor Bahru (JB), Malaysia
Google Site Search