ProComSol develops HART communicators for mobile device software that bridges the gap between HART Protocol devices, allowing for configuration, monitoring, calibrating, and troubleshooting of HART instruments in industrial plants.
Mobile :: Brands Masthead
PIE 422 14-Type Thermocouple Calibrator

PIE 422 14-Type Thermocouple Calibrator

Product Description

 
 
 
   
 
  • Automatic Stepping & Ramping
  • Larger Display with Backlight
    Easy viewing in dark locations
  • More Resistant to Accidental Damage
    Rubber Boot and Stronger Switches
  • Separate Battery Compartment
    No more removing housing with screwdriver to replace batteries
    Calibration seals remain intact
  • More Accurate and Repeatable
    NIST Traceable Cold Junction Sensor in isothermal block
  • Easily Change Thermocouple Types
    Reconfigure without resetting calibrator
  • Verify Cold Junction Temperature & Output
    Secondary display of compensated millivolt setting and cold junction temperature
  • Includes Certificate of Calibration
    All PIE Calibrators come with a free signed and dated certificate. Altek’s come only with an unsigned Statement of Calibration Practices with a certificate of calibration available for an extra charge.
 
 
 
 
 
 
 
  • Calibrate Milliamp Instruments
    Source 0.000 to 24.000 mA & -25.00 to 125.00% of 4-20 mA
    Read 0.000 to 24.000 mA & -25.00 to 125.00% of 4-20 mA
    Read -60.00 to +60.00 VDC
    Simulate 2-Wire Transmitter, Power & Read Transmitters
    Menu Selectable 250 Ohm resistor for HART compatibility
  • Calibrate with Lab Accuracy
    Accurate to ±(0.01% of Reading + 0.002 mA)
    PIE 434 is more accurate than similar calibrators – within ±0.004 mA at 20 mA output!
  • Easy-to-Read Backlit Display
  • Locate Loop Current Leakages
    Automatic indication of Loop Current and Leakage Current. Measure ground current leakage from faulty wiring, flooded conduit and corrosion bridges. Leakage typically appears as a Zero Shift and helps you decide if the transmitter needs calibration or if there is a problem in the loop wiring.
  • Faster Calibrations
    Three output EZ-CHECK switch
    2 speed EZ-DIAL
    Stepping & Ramping
  • Includes Rubber Boot, Deluxe Hands Free Carrying Case & Test Leads
  • Optional Accessories
    AC Adaptor 120 V (020-0101); 240 V (020-0100)
    NiMh Batteries & Charger 120 VAC/12V DC (020-0103)
    Magnetic hanging strap(020-0236)

 

 
 
 
 
 
 