ABB Coriolis mass flowmeter CoriolisMaster FCB130 and FCB150

ABB Coriolis mass flowmeter CoriolisMaster FCB130 and FCB150

Product Description

 
 
 
 
 
 
CoriolisMaster FCB100 series of compact system integration flowmeters feature low pressure drop, high flow capacity, high speed RS485 Modbus communication and 2 digital outputs.
The FCB100 series delivers: 
  • Superior accuracy and speed for filling applications
  • Full parameter access with up to 115 kBaud 
  • Aluminum housing or all stainless steel solution
  • DTM based diagnostic and operability functions   
The sensor delivers: 
  • Multivariable measurement of mass flow, density and temperature in one device
  • Low pressure drop save 25 % on pump energy costs compared to other brands
  • Wide measurement span in a single meter
FCB150 adds: 
  • DensiMass: High accuracy concentration measurement, watercut and net-oil computing as well as net-mass and net-volume measurement
  • FillMass: Filling application software with integrated precounter, over- and underfill correction and contact output for valve control 
 
General specifications:  
  • Nominal sizes / measuring ranges
– DN 15 (1/2 in.) / 0 to 8,000 kg/h (17,637 lb/h)
– DN 25 (1 in.) / 0 to 35,000 kg/h (77,162 lb/h)
– DN 50 (2 in.) / 0 to 90,000 kg/h (198,416 lb/h)
– DN 80 (3 in.) / 0 to 250,000 kg/h (551,156 lb/h)
– DN 100 (4 in.) / 0 to 520,000 kg/h (1,146,404 lb/h)
– DN 150 (6 in.) / 0 to 860,000 kg/h (1,895,975 lb/h)
  • Ex approvals– ATEX zone 0/1/2, cFMus Div 1/2 and zone 0/1/2      
  • Wetted materials– 1.4404 / 1.4435 (316L) or Hasteloy C
Accuracy for liquids
FCB130
– Mass and volume: 0.4 % o. r. / 0.25 % o. r.
– Density: 10 g/l
FCB150
– Mass: 0.15 % o. r. / 0.1 % o. r., volume: 0.15 % o. r.
– Density: 2 g/l or 1 g/l
  • Measuring medium temperature
FCB130
–  -50 to 160 °C (-58 to 320 °F)
FCB150
–  -50 to 205 °C (-58 to 400 °F)
  • Outputs – 2 digital out (pulse, frequency, contact), – Modbus
  • Power supply – 11 to 30 V DC

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
   