+6012-798 8581
info@rex-instruments.com.my
clear
Home
About Us
Products
AMS Solutions
AMS Trex Device Communicator
AMS 2140 Machinery Health Analyzer
Ex-Proof Smartphones/Tablets
Ex-Proof Smartphones
Ex-Proof Tablets (Android)
Ex-Proof Tablets (Windows)
Ex-Proof Portable Torch/HandLamps/Headtorches
Ex-Proof LED Torch
Ex-Proof Headtorces
Ex-Proof HandLamps
Ex-Proof LED Torch-Proof Mobile Lighting (Area Lights)
Thermal Imaging Cameras
Handheld Thermal Camera
Acoustic Thermal Camera
Firefighting Thermal camera
Ex-Proof Thermal Camera
HART Communicators
HART Modems
HART Communicator Software/Apps
HART Communicator Windows Systems
HART Communicator Android Systems
HART Communicator iOS System
License Subscription
Accessory
Instrumentation
Pressure Measurement
Temperature Measurement
Level Measurement
Flow Measurement
Oil Measurement
Positioners
Recorders and Controllers
Actuators
Calibration Test Bench
Calibration work Bench
Calibration Comparator Pump
Industrial Portable Torch/HandLamps/Headtorches
Industrial Torches
Industrial Handlamps
Industrial Headtorches
Industrial Mobile Lighting (Area Lights)
Multifunction Calibrator
Frequency Calibrator
Milliamp Loop Calibrator
Multifunction Process Calibrator
pH Calibrator
Thermocouple Calibrator
RTD Calibrator
Voltage calibrator
Measurement Meters
Multimmeters
Infrared Thermometer
Pressure Calibrator
Temperature Calibrator
Digital Pressure Gauge
Valve
Flow Control Valve
IoT Ball Valve
Brands
ABB
ECOM
EMERSON
GOALTEK
GENTOS
HAWK MEASUREMENT
HIKMICRO
KELLER
MIB
PIE
PROCOMSOL
RUEGER
SPMK
TRADINCO
VALCOM TERRANOVA
Careers
Contact Us
home
>
Products
>
Instrumentation
>
KELLER DCX-22AA Pressure Level loggers
KELLER DCX-22AA Pressure Level loggers
Please enter valid quantity.
Whatsapp
Email
KELLER DCX-22AA Pressure Level loggers
Product Description
Description
Data
The DCX-22AA data loggers compensate for changes in air pressure by means of a separate, water-tight absolute pressure sensor with a stainless steel separating diaphragm. Unlike gauge pressure systems with a capillary tube, this system is completely resistant to moisture and can therefore be immersed. Thanks to their long-life battery, they can keep measuring the water level, water pressure and temperature for years (up to 10 years at a rate of one measurement per hour). The logger can be configured using the supplied software (measurement interval, incident management, delayed measurement start etc.) and data that has been read can be displayed in a graph or chart, corrected using air pressure values, converted into fill levels or other units, and exported.
The data collector DCX-22AA measures and records ground water levels using KELLER’s two sensor AA-technology (absolute-absolute). The submersible depth sensor measures the water level. Barometric pressure variations are measured and compensated with the built-in waterproof air pressure sensor which is mounted in the electronics housing at the top of the borehole. There are no ventilation tubes; this means the DCX-22AA data logger is very rugged and suitable for reliable applications in humid and wet environments. Even short periods of immersion and flooding will not cause a problem
The electronics housing is mounted at the top of the borehole to give easy access for data downloading. The level sensor (diameter 22 mm) is connected via a sealed cable to the bottom of the electronics housing. Installation is quick and simple, using fixing devices in various sizes, suitable for cap lock units of different manufacturers and for well access points starting from 1” (caps starting at 2” include a hole to lower a dip meter). Thus enabling measuring stations to be set up at considerably lower costs compared to conventional systems.
The electronics employ the latest microprocessor technology, which give high accuracy and resolution for the pressure and temperature signals from both the depth sensor and the barometric sensor. The measured values are mathematically compensated for all linearity and temperature errors of the pressure sensors. The use of a non-volatile memory ensures high data security. The modular design of the DCX-22AA offers the user the two options for collecting the data. Standard design requires the user to visit the location, connect via data-cable and download data. The optional ARC1 unit allows the transmission of data, and instructions (re-programming) to the data-collector from / to a remote location. The data can be sent to any mobile phone as a short message (SMS). OPTIONS ARC1 Data transmission module (see separate datasheet ARC1)
Pressure Ranges 0…5 to 0…10 mH2O
Total Error Band ±0,1 %FS @ -10…40 °C
Reading Capacity 114'000 measuring points
Dimensions ø 22 mm
Special Characteristics With integrated barometer
You May Also Like
Rueger Diaphragm pressure gauges PMX
VALCOM OMD atmospheric oil mist detection
VALCOM T7B Level/Density transmitter
Rueger Thermo-Standard TSI
VALCOM T76 Pressure & Differential Pressure Transmitter
Hawk Measurement AWRF234 Sultan Flow Acoustic Wave Open Cha...
mail