clear
ABB Coriolis mass flowmeter CoriolisMaster FCH130 and FCH150

ABB Coriolis mass flowmeter CoriolisMaster FCH130 and FCH150

Product Description

 
 
 
 
 
 
CoriolisMaster FCH100 series of compact hygienic system integration flowmeters feature low pressure drop, high flow capacity, high speed RS485 Modbus communication and 2 digital outputs.
The FCH100 series offers on top EHEDG certified cleanability with polished wetted materials.
With no up or downstream piping requirements the compact flowmeters can be installed in the tightest spaces, enabling applications not possible before.
The FCH100 series delivers: 
  • EHEDG, hygienic certification
  • Superior accuracy and speed for filling applications
  • Full parameter access with up to 115 kBaud
  • Aluminum housing or all stainless steel solution
  • DTM based diagnostic and operability functions   
The sensor delivers: 
  • Multivariable measurement of mass flow, density and temperature in one device
  • Low pressure drop save 25 % on pump energy costs compared to other brands
  • Wide measurement span in a single meter
FCH150 adds: 
  • DensiMass: High accuracy concentration measurement, watercut and net-oil computing as well as net-mass and net-volume measurement
  • FillMass: Filling application software with integrated precounter, over- and underfill correction and contact output for valve control 
General specifications:  
  • Nominal sizes / measuring ranges
– DN 25 (1 in.) / 0 to 35,000 kg/h (77,162 lb/h)
– DN 50 (2 in.) / 0 to 90,000 kg/h (198,416 lb/h)
– DN 80 (3 in.) / 0 to 250,000 kg/h (551,156 lb/h)
  • Ex approvals– ATEX zone 0/1/2, cFMus Div 1/2 and zone 0/1/2          
  • Wetted materials
– 1.4404 / 1.4435 (316L) 
Accuracy for liquids
FCH130
– Mass and volume: 0.4 % o. r. / 0.25 % o. r.
– Density: 10 g/l
FCH150
– Mass: 0.15 % o. r. / 0.1 % o. r., volume: 0.15 % o. r.
– Density: 2 g/l or 1 g/l
  • Measuring medium temperature
FCH130
–  -50 to 160 °C (-58 to 320 °F)
FCH150
–  -50 to 205 °C (-58 to 400 °F)
  • Outputs – 2 digital out (pulse, frequency, contact), – Modbus
  • Power supply – 11 to 30 V DC

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
   
mail