+6012-798 8581
info@rex-instruments.com.my
clear
Home
About Us
Products
AMS Solutions
AMS Trex Device Communicator
AMS 2140 Machinery Health Analyzer
Ex-Proof Smartphones/Tablets
Ex-Proof Smartphones
Ex-Proof Tablets (Android)
Ex-Proof Tablets (Windows)
Ex-Proof Portable Torch/HandLamps/Headtorches
Ex-Proof LED Torch
Ex-Proof Headtorces
Ex-Proof HandLamps
Ex-Proof LED Torch-Proof Mobile Lighting (Area Lights)
Thermal Imaging Cameras
Handheld Thermal Camera
Acoustic Thermal Camera
Firefighting Thermal camera
Ex-Proof Thermal Camera
HART Communicators
HART Modems
HART Communicator Software/Apps
HART Communicator Windows Systems
HART Communicator Android Systems
HART Communicator iOS System
License Subscription
Accessory
Instrumentation
Pressure Measurement
Temperature Measurement
Level Measurement
Flow Measurement
Oil Measurement
Positioners
Recorders and Controllers
Actuators
Calibration Test Bench
Calibration work Bench
Calibration Comparator Pump
Industrial Portable Torch/HandLamps/Headtorches
Industrial Torches
Industrial Handlamps
Industrial Headtorches
Industrial Mobile Lighting (Area Lights)
Multifunction Calibrator
Frequency Calibrator
Milliamp Loop Calibrator
Multifunction Process Calibrator
pH Calibrator
Thermocouple Calibrator
RTD Calibrator
Voltage calibrator
Measurement Meters
Multimmeters
Infrared Thermometer
Pressure Calibrator
Temperature Calibrator
Digital Pressure Gauge
Valve
Flow Control Valve
IoT Ball Valve
Brands
ABB
ECOM
EMERSON
GOALTEK
GENTOS
HAWK MEASUREMENT
HIKMICRO
KELLER
MIB
PIE
PROCOMSOL
RUEGER
SPMK
TRADINCO
VALCOM TERRANOVA
Careers
Contact Us
home
>
Products
>
Hawk Measurement Gladiator G3 Microwave Switch
Hawk Measurement Gladiator G3 Microwave Switch
Please enter valid quantity.
Whatsapp
Email
Hawk Measurement Gladiator G3 Microwave Switch
Product Description
Description
Technical Data
The Gladiator Gen 3 Microwave Switch can be used for blockage detection, barrier detection, machine detection, collision detection for protection, point level measurement, and detection of objects or material between two points.
Principle of Operation
A beam of microwave energy passes from a sender unit to a separate receiver in bursts approximately 200 times per second. If the path between the sender and receiver is blocked by any object or material which absorbs or reflects microwave energy, then the receiver will not be able to detect the signal. The presence or absence of the signal at the receiver is used to switch a relay for indication or control purposes.
Certifications
IECEx Zone 20/21, Zone 21
Ex ta tb IIIC T* Da Db Tamb -30°C to +80°C / Tamb = -30°C to +55°C (model dependent)
IP66
State of the art Circular transmission
Backwards compatible with all Gladiator Microwave generations
LCD push button setup / diagnostics on remote amplifier
Simple sensitivity adjustment and calibration on Integral system
Ranges up to 1200 meters (3937 ft)
Primary Areas of Application Liquid Level:
Tank or Vessel
Measuring Range: 10cm (4in) - 1200m (3937ft)
Communications: GosHawk, Modbus, Modbus over Ethernet TCP/IP, 4-20mA
Maximum Operating Pressure: 6 Bar
Mounting: 3.5" male NPT thread or four 10mm (0.4") holes in flange, MA12 / MA13 adjustable mounting bracket
You May Also Like
ABB Gauge pressure transmitter 266GRT
ABB Magnetic level gauge switch LMS200
ABB Guided wave radar LWT300 series
KELLER DCX-22-ECO Pressure Level loggers
ABB Magnetostrictive Level Transmitter LMT200
Rueger Thermo-Hit TH1-TH
mail